12KW Belt Power System For SITRAK Emergency Command Vehicle

12KW Belt Power System For SITRAK Emergency Command Vehicle12KW Belt Power System For SITRAK Emergency Command Vehicle猛士CTM131-12KW双取力发电机供电系统12KW Belt Power System For SITRAK Emergency Command Vehicle
12KW Belt Power System For SITRAK Emergency Command Vehicle
12KW Belt Power System For SITRAK Emergency Command Vehicletotal picture:1
  • 12KW Belt Power System For SITRAK Emergency Command Vehicle
  • Product Model : S9C12000-CTM131-2
    Idle Power : 12.0KVA[Engine Speed:750]
  • Alternator Brand : SICOTE
    Alternator Model : S4C6000PLD [QTY:2]
    Control Brand : SICOTE
    Control Model : S4C12000-5U-230
  • AC Voltage : 230V[Voltage Can Change]
    Frequency : 50HZ[Can Change]
    AC Phase : Single Phase
    Equipment Noise : 0 DB [ LP7M ]
Related Product
12.0KVA
12KW SICOTE Vehicle Silent Generator Set (single-phase 50HZ)
Engine Model : 4D85-17,Alternator Model : ST12-50D-4F,Control Model : GCU4000,12KW SICOTE Vehicle Silent Generator Set (single-phase 50HZ)12KW SICOTE Vehicle Silent Generator Set (single-phase 50HZ)
12KW Super Silent Traveling Diesel Generator
Engine Model : 4DW91-29D,Alternator Model : ST12-50D-4F,Control Model : GCU4000,12KW Super Silent Traveling Diesel Generator12KW Super Silent Traveling Diesel Generator
12KW Parking Take-off Generator Set
,Alternator Model : SCT12-3-YC,Control Model : GCU4000,12KW Parking Take-off Generator Set12KW Parking Take-off Generator Set
12KW Belt Power System For Brave Warrior CTL181
,Alternator Model : S9C12000,Control Model : S9C12000-5U-230,12KW Belt Power System For Brave Warrior CTL18112KW Belt Power System For Brave Warrior CTL181
12KW Belt Power System For CTM131
,Alternator Model : S9C12000,Control Model : S9C12000-5U-230,12KW Belt Power System For CTM13112KW Belt Power System For CTM131
Perfect Gifts
Wuxi Sicote Power Technology CO., Ltd. produce 12KW Belt Power System For SITRAK Emergency Command Vehicle;
12KW Belt Power System For SITRAK Emergency Command Vehicle Tech Data
◆ Tech Data Of SICOTE Belt Alternator {Need 2 belt alternator} Idle Power : 12.0KW {Product Model:S9C12000-CTM131-2}
Alternator Model Single Belt Alternator Tech Data Control Model
S4C6000PLD Engine Speed 750 RPM {Idle Speed} 1000 RPM 1300 RPM 1600 RPM 2000 RPM {Working} S4C12000-5U-230
Alternator Voltage Output Current 108A 113A 124A 127A 130A Controler Style
DC 56 V Output Power 6.0KW { Idle Power } 6.3KW 6.9KW 7.1KW 7.3KW { Max Power } 5U Standard Cabinet
working temperature : -40℃ — +100℃; storage temperature : -40℃ — +70℃; relative humidity : 95±3% (at +40℃)
Cooling Method Of Belt Alternator :Air-cooled
Meet the standard:GJB150.9A-2009 , GJB150.10A-2009 , GJB150.11A-2009 , GJB150.16A-2009
◆ Electrical Data Of Belt Power System※ Has automatic acceleration function ※ {AC Voltage: 220/230/240Can Change}
AC Voltage Frequency AC Voltage
stability time
Frequency
stability time
AC input Automatic
switching
Manual
Acceleration
Remote
Control
UPS Battery Data Single Battery Size
Ports Protect Function Charge Warning AH QTY L W H
230±2V 50±0.1HZ ≤1S ≤3S optional 150AH 4 483 170 238
◆ List Of SICOTE Belt Power System

SICOTE

Belt Alternator

SICOTE

Control System

SANTAK

Battery

Converter
Device
DC To DC
Device
Frame Pulley Tension Pulley
QTY
Guide Wheel
QTY
Bolt
Nut
Speed
Device
Power
Cable
Belt
QTY Weight QTY Weight AH QTY Weight
2 PCS 22Kg 1 PCS 53Kg 150AH 4 166Kg 0 1 1 1 PCS 1 PCS 4 PCS 1 1 1 2 PCS
[Other instructions]: Users can download the information by the vehicle number in our website
  • Less than truckload transportation (freight collect)
  • Need Time : 3-10 Days [ In China ]
  • Charging Method : Order billing (basic cost)
  • Basic Weight : Shipping by the buyer or the instructions under the contract
  • Free Scope : This distribution is No Free distribution
  • Logistics Scope : FOB shanghai  
  • Large cargo loading (freight collect)
  • Need Time : 3-4 Days [ In China ]
  • Charging Method : Order billing (basic cost)
  • Basic Weight : Shipping by the buyer or the instructions under the contract
  • Free Scope : This distribution is No Free distribution
  • Logistics Scope : FOB shanghai  
  • Special car express (freight collect)
  • Need Time : 2-3 Days [ In China ]
  • Charging Method : Order billing (basic cost)
  • Basic Weight : Shipping by the buyer or the instructions under the contract
  • Free Scope : This distribution is No Free distribution
  • Logistics Scope : FOB shanghai  
Diesel generator set warranty repairs and claims provisions
A quality guarantee period
1. diesel generator set from the factory date twelve months or crew running 1000 hours, the end of one of these two time limits to achieve that quality assurance.
The contract otherwise special agreement subject to contract.
Second, the quality assurance of free maintenance range
User should be in accordance with the generator sets and ancillary components (including engine, generator) Use and maintenance manual requirements for normal use and maintenance, product quality assurance of failure by the service engineer or authorized personnel (including the supply vendor personnel permitted) test due to failure caused by quality defects or assembly of the product itself, I am responsible for free replacement parts or maintenance.
Does not belong to the scope of quality assurance during the free maintenance:
Transport their own installation and maintenance works damaged by direct person in charge of compensation.
2. to be demolished without the consent of the Company.
3. without the damage caused to the Company agreed to change the product without structure or unauthorized installation of other devices.
4. do not follow the product manual installation, maintenance requirements for installation, maintenance and damage.
5. Fails to product specification stipulates that the use of models and brands improper, can not guarantee the quality of lubricating oil.
6. Fails to use models, product specification provides brand properly, can not guarantee the quality antifreeze.
7. Fails to maintenance requirements, timing replace the oil filter, diesel filter, air filter.
8. unused product brochures under the oil filter, diesel filter, air filter.
Fourth, the responsibilities and obligations of the Company
The company commitment to quality assurance free maintenance during the period of direct costs, do not bear the resulting overheads and indirect losses.
Taking into account regional differences, our service response time in different parts of the contract in accordance with the development of different response time included in the contract areas.
Responsibilities and obligations of the corporate users
1 user is responsible for the use and maintenance in accordance with the requirements of the specification.
Save a true record of the use and maintenance of all operating, not fraud.
Assist service engineers or authorized personnel (including the supply vendor personnel permitted) check and determine the cause of the malfunction.
      
No Information Now